Kv -300 – KEYENCE Visual KV Series User Manual
Page 320

7.7 Non-procedure Mode Programming
KV-300 Series Only
KV
-300
KV-10/80
Chapter 7 KV-L2 Serial Interface Module
1-296
7
5. First relay no. +4
Turns ON when a break signal of approximately 160 msec is transmitted. Automati-
cally turns OFF after transmission is completed. Transmission is enabled while the
first relay no. +3 is OFF.
Use the SET instruction or KEEP instruction to turn the relay ON/OFF.
Assigning data memory addresses
200 DM addresses, including the first DM no., are assigned.
The assigned DM addresses have the following functions.
■ Number of data bytes
The number of bytes in the first DM no. +0 and the first DM no. +100 becomes a
binary value. Write the binary data using the LDA/STA instruction or DW instruction.
■ Text data
Enter the text data in ASCII, by byte per DM. ("00" is entered in the 8 high-order bits
and ASCII code is entered in the 8 low-order bits.)
Write the text data using the LDA/STA instruction or DW instruction.
DM No.
Assigned data
First DM No. +0
Number of bytes of text data loaded
+1 to +99
Text data to be received
+100
Number of bytes of text data to be received
+101 to +199
Text data to be transmitted
KVHKA Chap 07_5to10.p65
08.3.11, 11:18 AM
296