3 connector wiring, Kv -300, Wiring rs-232c cables – KEYENCE Visual KV Series User Manual
Page 272: Wiring rs-422a cables

7.3 Installation
KV-300 Series Only
KV
-300
KV-10/80
Chapter 7 KV-L2 Serial Interface Module
1-248
7
7.3.3
Connector Wiring
Wiring RS-232C cables
D-Sub 25-pin connector
Terminal block
Wiring RS-422A cables
Note: Do not short-circuit the SG terminal with any other signal terminal. Doing so
may cause failure of the unit.
Recommended communications cable (for use with RS-422A)
1
23
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
2
3
4
5
7
SD
RD
RS
CS
SG
KV-L2
Unit designated
as DCE
2
3
4
5
6
20
7
SD
RD
RS
CS
DR
ER
SG
Unit designated
as DTE
2
3
4
5
7
SD
RD
RS
CS
SG
KV-L2
2
3
4
5
6
20
7
SD
RD
RS
CS
DR
ER
SG
D-Sub 25-pin
connector
SG
(SG)
SDB RDB
SDA
(SD)
RDA
(RD)
1
3
5
2
4
3
5
1
SD
RD
SG
KV-L2
2
3
4
5
6
20
7
SD
RD
RS
CS
DR
ER
SG
3
5
1
SD
RD
SG
KV-L2
2
3
4
5
6
20
7
SD
RD
RS
CS
DR
ER
SG
Unit designated
as DTE
Unit designated
as DCE
KV-L2 terminal nos.
SG
(SG)
SDB RDB
SDA
(SD)
RDA
(RD)
1
3
5
2
4
KV-L2 terminal nos.
3
2
5
4
1
SDA
SDB
RDA
RDB
SG
SDA
SDB
RDA
RDB
SG
KV-L2
External unit
Item
Specification
Cable type
Shielded cable
Logarithm
3P
Maximum conductor resistance at 20°C (68°F)
88.0 Ω/km
Maximum insulation resistance
10.000 MΩ·km
Withstand voltage
500 VDC for 1 min
Maximum electrostatic capacity (1 kHz)
60 nF/km on average
Characteristic impedance (100 kHz)
110 ±10Ω
KVHKA Chap 07_1to4.p65
08.3.11, 11:18 AM
248