KEYENCE Visual KV Series User Manual
Installation, User's manual, Visual kv series

User's Manual
Visual KV Series
1
Installation
96M0364
How this manual is organized:
The Visual KV Series User’s Manual is composed of 3 separate
manuals; 1-Installation, 2-Support Software, 3-Programming.
Please read each manual relevant to your purpose.
1
Support
Software
1. Introduction
2. Editor
3. Simulator
4. Monitor
5. Appendices
2
Programming
1. Programming
2. Instructions
3. Interrupts
4. High-speed Counters
5. Positioning Control
6. Interrupts, High-speed
Counters, Positioning
Control
7. Serial Communication
8. Programming
Examples
3
INDEX
Installation
1. Configuration and
Specifications
2. System Installation
3. Access Window
4. KV-D20 Operator
Interface Panel
5. KV-10/80 Hardware
6. Handheld
Programmer
7. KV-L2 Serial Interface
Module
8. KV-AN6 Analog I/O
Module
9. KV-AD4/DA4 Analog
I/O Unit
10. Troubleshooting
11. Appendices
Visual KV Ser
ies 1 Installation
User’
s Man
ual
A5WW1-MAN-0069
Specifications are subject to change without notice.
AUSTRIA
Phone: +43-2236-378266-0
BELGIUM
Phone: +32 2 716 40 63
CHINA
Phone: +86-21-68757500
CANADA
Phone: +1-905-696-9970
CZECH REPUBLIC
Phone: +420 222 191 483
FRANCE
Phone: +33 1 56 37 78 00
GERMANY
Phone: +49-6102-36 89-0
HONG KONG
Phone: +852-3104-1010
KOREA
Phone: +82-31-642-1270
HUNGARY
Phone: +36 14 748 313
ITALY
Phone: +39-2-6688220
JAPAN
Phone: +81-6-6379-2211
MEXICO
Phone: +52-81-8220-7900
NETHERLANDS
Phone: +31 40 20 66 100
POLAND
Phone: +48 71 36861 60
MALAYSIA
Phone: +60-3-2092-2211
SINGAPORE
Phone: +65-6392-1011
SLOVAKIA
Phone: +421 2 5939 6461
SWITZERLAND
Phone: +41 43 455 77 30
TAIWAN
Phone: +886-2-2718-8700
THAILAND
Phone: +66-2-369-2777
UK & IRELAND
Phone: +44-1908-696900
USA
Phone: +1-201-930-0100
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211
Copyright (c) 1999 KEYENCE CORPORATION. All rights reserved.
084024E 0079-3 96M0364 Printed in Japan
Document Outline
- Safety Precautions
- Note to User
- Restriction on Acquiring the CE Marking
- Features of the Visual KV Series
- Compatibility with Conventional KV Series Peripheral Units
- Cautions when Using the Serial Port
- How this manual is organized
- Contents
- WARRANTIES AND DISCLAIMERS
- Caution
- Chapter 1 Configuration and Specifications
- 1.1 System Configuration
- 1.2 Specifications
- 1.3 Common I/O Specifications of BasicUnits
- 1.4 KV-10AR/AT(P)/DR/DT(P) (10-I/O Basic Unit)
- 1.5 KV-16AR/AT(P)/DR/DT(P) (16-I/O Basic Unit)
- 1.6 KV-24AR/AT(P)/DR/DT(P) (24-I/O Basic Unit)
- 1.7 KV-40AR/AT(P)/DR/DT(P) (40-I/O Basic Unit)
- 1.8 KV-E4X/E8X/E16X (Expansion Input Unit)
- 1.9 KV-E4R/E4T/E8R/E8T(P)/E16R/E16T(P)(Expansion Output Unit)
- 1.9.1 Part Names and Functions
- 1.9.2 Output Specifications
- 1.9.3 Terminal Layout Drawings and Input Circuit Diagrams
- KV-E4R [4-I/O expansion output unit (relay output type)]
- KV-E4T [4-I/O expansion output unit (transistor output type)]
- KV-E8R [8-I/O expansion output unit (relay output type)]
- KV-E8T(P) [8-I/O expansion output unit (transistor output type)]
- KV-E16R [16-I/O expansion output unit (relay output type)]
- KV-E16T(P) [16-I/O expansion input unit (transistor output)]
- 1.9.4 Dimensions
- 1.10 KV-E4XR/E4XT(P) (Expansion I/O Unit)
- 1.11 KV-D20 (Operator Interface Panel)
- Chapter 2 System Installation
- 2.1 Installation Environment
- 2.2 Connecting Visual KV SeriesExpansion Units
- 2.3 Inspection and Maintenance
- Chapter 3 Access Window
- Chapter 4 KV-D20 Operator Interface Panel
- Chapter 5 KV-300 and KV-10/80 Hardware
- 5.1 System Configuration
- 5.2 Module/Unit Specifications
- 5.2.1 Wiring: KV-U4 Power Supply Module
- 5.2.2 Wiring: KV-U5 DC Power Distribution Module
- 5.2.3 Wiring: KV-300 CPU
- 5.2.4 Wiring: KV-C16X/C32X Connector Input Module
- 5.2.5 Wiring: KV-C32T/B16R/B16S Connector Output Module
- 5.2.6 Wiring: KV-R1A I/O Distribution Module
- 5.2.7 Wiring: KV-R8X/R16X/R8R/R16R/R8T/R16T I/O TerminalModules
- 5.2.8 Module Names and Functions
- 5.2.9 Peripheral Equipment Names and Functions
- 5.3 Module/Unit Connections
- 5.3.1 Environmental Requirements
- 5.3.2 Installation Guidelines
- 5.3.3 Assembling the System
- 5.3.4 Mounting to the DIN Rail
- 5.3.5 Removing the Terminal Block
- 5.3.6 Connecting the AC Power Supply Module and DCPower Distribution Module
- 5.3.7 I/O Connectors
- 5.3.8 I/O Terminal Modules: Communication Cables andPower Distribution
- 5.3.9 Connector Assembly Instructions
- 5.3.10 KV-300 CPU I/O Indicators
- 5.3.11 KV-10/80 Expansion Units
- 5.3.12 Mounting Environment
- Chapter 6 Handheld Programmer
- 6.1 Using the Handheld Programmer
- 6.2 Basic Operations
- 6.3 Functions
- Function Nos. list
- ALL CLEAR [FNC60]
- HANDHELD PROGRAMMER CLEAR (P3E CLEAR) [FNC61]
- COUNTER CLEAR (CTR CLEAR) [FNC62]
- HIGH-SPEED COUNTER CLEAR (HIGH-SPEED CTR CLR) [FNC63]
- ALL DATA MEMORY CLEAR (DM ALL CLEAR) [FNC64]
- ALL LATCHING RELAYS RESET (L-RELAY ALL RST) [FNC65]
- PROGRAM SENT OR RECEIVED (COMMUNICATION —) [FNC66]
- OFFLINE EDITOR START (OFFLINE EDITOR) [FNC67]
- OFFLINE EDITOR STOP (QUIT OFF-L EDIT) [FNC68]
- TIMER/COUNTER CURRENT VALUE CHANGE(CHG: T/C CURT-V) [FNC69]
- TIMER/COUNTER SETTING CHANGE (CHG: T/C SET-V) [FNC70]
- RELAY ON/OFF (FORCED SET/RESET) [FNC71]
- WRITE INTO DATA MEMORY (DM WRITE) [FNC72]
- READ TRIMMER SETTING(TRIMMER MONITOR) [FNC73]
- SYNTAX CHECK (PROGRAM CHECK) [FNC74]
- PROGRAM CAPACITY CHECK (PROGRAM SIZE) [FNC75]
- 6.4 Memory Card
- Chapter 7 KV-L2 Serial Interface Module
- 7.1 Outline
- 7.2 Configuration
- 7.3 Installation
- 7.4 Software Setup
- 7.5 KV Mode Programming
- 7.6 Display Interface Mode Programming
- 7.7 Non-procedure Mode Programming
- 7.8 Troubleshooting Guide
- 7.9 Specifications
- 7.10 Command List
- Chapter 8 KV-AN6 Analog I/O Module
- 8.1 Outline
- 8.2 Configuration
- 8.3 Installation
- 8.4 Programming
- 8.4.1 Input Characteristics (A/D)
- 8.4.2 Calculating Input Data (A/D)
- 8.4.3 Output Characteristics (D/A)
- 8.4.4 Calculating Output Data (D/A)
- 8.4.5 Assigning Data Memory (DM) Addresses
- 8.4.6 Reading Analog Input
- 8.4.7 Measuring Analog Input Average
- 8.4.8 Writing Analog Output
- 8.4.9 Converting Analog Input to Analog Output
- 8.5 KV-AN6 Appendices
- Chapter 9 KV-AD4/DA4 Analog I/O Unit
- Chapter 10 Troubleshooting
- Appendices
- Appendix A. Specifications and Dimensions[Visual KV Series]
- Appendix B. Specifications and Dimensions[KV-300 Series]
- Appendix C. Ladder Program List
- Appendix D. A/D and D/A Conversion Tables [KV-AN6]
- Index
- WARRANTIES AND DISCLAIMERS: