Example program, Kv -300 – KEYENCE Visual KV Series User Manual
Page 293

7.5 KV Mode Programming
KV-300 Series Only
KV
-300
KV-10/80
Chapter 7 KV-L2 Serial Interface Module
1-269
1
7
Example program
Sample program
Text data received from an external device is converted to binary data and is
written in the DM0000 after conversion.
3. The ASCII-converted value is loaded to data memory addresses as follows.
The number of DM addresses used is the value specified as the number of bytes
in the ASCII string.
4. Program for converting binary data to ASCII
The following example shows a program that converts binary data to an ASCII
string during transmission of text data. The converted values are written to data
memory addresses starting from DM9301. The total number of digits, including
the decimal point, is written to DM9300.
0000
2315
1000
1000
2807
2315
#09301
#00000
DIFU
SET
(
)
< DW >
< DW >
DM9602
DM9603
DM****+0
First DM address of ASCII string (data 1 of text data)
:
:
DM****+98
Last DM address of ASCII string (data 99 of text data)
2008
2314
3000
1100
1100
2314
DIFU
3000
RES
(
)
#00000
< DW >
DM9600
#01500
< DW >
DM9601
#03000
< DW >
DM9700
#01000
< DW >
DM9701
DM1500
< LDA>
DM1200
< STA >
DM1501
< LDA >
DM2001
< STA >
DM1502
< LDA >
DM2002
< STA >
KVHKA Chap 07_5to10.p65
08.3.11, 11:18 AM
269