Visual kv series – KEYENCE Visual KV Series User Manual
Page 177

Chapter 4 KV-D20 Operator Interface Panel
1-153
1
4
Visual KV
Series
1.
Turn on Bits 0, 5, and 6 of DM1676 ($0061) to enable changing the screen between the
operator, switch comment, and lamp comment screens.
2.
With the MEMSW instruction, turn on SW3-3 of the memory switch ($0800) to set the 24-
bit high-speed counter.
3.
Set the high-speed counter in double multiplication mode and reset high-speed counter
0.
4.
High-speed counter 0 starts when relay 1000 is turned on. Customized lamp 1 illuminates
while the high-speed counter is operating.
5.
The ON/OFF status of relay 1000 is switched every time customized switch F1 is
pressed. (Alternating circuit)
6.
The current value of high-speed counter 0 and the outputs of comparators 0 and 1 are
reset when customized switch F2 is pressed.
7.
Customized lamp 2 illuminates when comparator 0 turns on.
8.
Customized lamp 3 illuminates when comparator 1 turns on.
9.
A flicker circuit is used to flash the titles.
When relay 1000 is turned on, assign relay 15000 to the device displayed on the first line
(specify "#55000" in DM1580), and set the attributes so that only the comment is dis-
played (Bit 8: ON) (DM1680 = $0100). Continue this operation for 500 ms.
After 500 ms, assign relay 15001 to the device displayed on the first line (specify
"#55001" in DM1580), and set the attributes so that only the comment is displayed (Bit 8:
ON) (DM1680 = $0100). Continue this operation for 1 second.
Repeat the operations above to flash the title.
10. Assign CTH0 to the device displayed on the second line (specify "#23000" in DM1581).
Set the attributes so that the decimal point position is "2" ($0002), the number of spaces
at the right end is "2" ($0020), a sign is used (Bit 9: ON), and changing the value is
disabled (Bit 15: ON) (DM1681 = $8222).
4.3 Examples of Ladder Programs
0011
0012
0013
0014
0015
0016
0017
0018
0019
0020
0021
0022
0023
0024
0025
0026
0027
ENDH
END
1000
2500
2003
2501
CTC0
CTC1
1000
T001
T000
2008
#23000
DM1581
DW
$8222
DM1681
DW
#22000
DM1582
DW
$0222
DM1682
DW
#22001
DM1583
DW
$0222
DM1683
DW
#55000
DM1580
DW
$0100
DM1680
DW
T000
#00005
#55001
DM1580
DW
$0100
DM1680
DW
T001
#00010
2505
2506
CTH0
RES
CTC1
RES
CTC0
RES
SFT
1000
D
1000
CLK
RES
5
6
7
8
9
10
ON for
1 scan
Always OFF
Alternating switch
Reset
High-speed counter comparator setting
Flashing title display
Use the comments of internal utility relays 15000 and 15001 as titles.
Display the current and preset values of high-speed
counter 0 (2-words with a sign and two decimal places)
KVHKA Chap 04.p65
08.3.11, 11:13 AM
153