KEYENCE Visual KV Series User Manual
Page 228

6.2 Basic Operations
Chapter 6 Handheld Programmer
1-204
6
Example 3: Entering application instruction
Entering "DIFD 1000"
Enter DIFFERENTIATE DOWN instruction
[FNC09].
Cursor automatically moves to operand position.
Enter "1000".
"DIFD 1000" has been set.
"DIFD 1000" has been entered.
RES
0
RES
0
0 0 0 0 2
N O P
F U N [ 0 9 ]
D I F D
OR
9
Cursor
(blinking)
D I F D 0 0 0 0 0
Cursor
(blinking)
N O P
Cursor
(blinking)
0 0 0 0 2
0 0 0 0 3
Cursor
(blinking)
ENT
R-SRCH
D I F D 0 1 0 0 0
0 0 0 0 2
Cursor
(blinking)
RES
0
FNC
ENT
R-SRCH
SET
1
RES
0
"DIFD 1000" has been entered.
Example 2: Entering timer/counter instruction
Entering "TMR006#00055"
Enter TMR instruction.
0 0 0 0 1
N O P
0 0 0 0 1
T M R 0 0 0 # 0 0 0 0 0
TMR
(T)
Cursor
(blinking)
T M R 0 0 6 # 0 0 0 0 0
ORB
6
Cursor
(blinking)
N O P
Cursor
(blinking)
0 0 0 0 1
0 0 0 0 2
Cursor
(blinking)
ENT
R-SRCH
ANB
5
ANB
5
T M R 0 0 6 # 0 0 0 5 5
0 0 0 0 1
Cursor
(blinking)
Cursor automatically moves to timer
No. position.
Enter "6" as timer No.
Move cursor to operand position.
Enter "55" as timer preset value.
"TMR006#00055" has been set.
"TMR006#00055" has been entered.
KVHKA Chap 06_1&2.p65
08.3.11, 11:16 AM
204