beautypg.com

Version 1.50, Ultra3000 drive-related enhancements, Ultra5000 drive-related enhancements – Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 340

background image

342

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Appendix A Ultraware Software Updates

Version 1.50

Ultra3000 Drive-related Enhancements

Changes two existing position comparators to permit the use of a position
window (Within Window and Outside Window) in addition to a Greater
Than and Less Than.

A new parameter, Absolute Direction, permits the user to specify the
direction of motion for each absolute index. Directions include: Forward
Uni-Directional, Reverse Uni-Directional, or Bi-Directional when
Position Rollover is Enabled.

A new parameter, Single-Turn Absolute, permits the user to specify
whether an SRS encoder should be considered an absolute feedback device
or not.

Extends the range of scaling for position signals when mapped to the
analog output.

Adds support for integrated Gear Motors.

Adds support for controlling Acceleration Feedforward in the Tuning
properties.

Additional scope attributes are now saved on the drive (Scale Type and
Samples Per Division).

Ultra5000 Drive-related Enhancements

Adds capability for two adjacent linear cam segments.

New motion library functions let the program define cam tables, queue
cam tables, and adjust the phasing of the cam.

Enhancements to link only code required for the current application
instead of the entire library using new compiler (2.x), but maintained
support of old compiler (1.x) when needed.

Fixes the executable size being included in calculations that determine if
there's enough space on the drive to copy a project to the archive branch.

Permits negative position values in a .csv files imported as cam tables.

Global Variables in monitor window can be displayed and edited in
decimal, hexadecimal and binary format.

Progress meter displays while transferring large variable arrays.

Eliminates crash that occurs while creating an online global variable when
there isn't enough space available.

Scope properties are now stored on the drive.

Adds these new faults:
Ground Short Circuit
Soft-Starting Fault
Power Module Over temperature
AC Input Phase Loss
Self-sensing Startup Error
Excessive CPU Load