Chapter 5 Configuring the Kinetix 3 Drive
2. Click OK.
The word Unassigned appears in the selected Channel in the Oscilloscope
window.
Understanding Kinetix 3
Status Displays
Status for the Kinetix 3 drive are displayed in the Monitor window. Signals from
oscilloscope channels may be used as data sources for the status table.
Status
Description Oscilloscope
Input Trigger
Oscilloscope
Output Trigger
Monitor Analog
Output
Signal
Fault Detail
Channel
Drive Status
Analog Command -
Velocity
Refer to Understanding the
Analog Window on page 237
X
X
X
X
X
Analog Command -
Current
Refer to Understanding the
Analog Window on page 237
X
X
X
X
X
Bus Voltage
The current measure of DC Bus
voltage.
X
X
X
Commutation Angle -
Degrees
Reports the position within the
motor electrical cycle in
degrees from -180 to 180
degrees.
X
X
X
X
X
Enabled
ON indicates the power stage
of the drive is enabled. As a
precondition, either software
or hardware enable must be
active, and the drive cannot
have any faults.
X
Fault Warning
Refer to Understanding the
Kinetix 3 Drive Branch on
page 225
X
Firmware Version
Refer to Understanding the
Service Information Window
on page 297
X
Motor Temperature
Reports the percentage of the
Motor Temperature Trip value,
that is based on the motors
continuous current rating,
thermal characteristics, and
time.
The Motor Temperature is an
indication of the level of
utilization of the motor's
current capability. When the
Motor Temperature reaches
100% a Motor Filter fault
occurs.
X
X
X
Current Operating
Mode
Refer to Understanding the
Kinetix 3 Drive Branch on
page 225
X