beautypg.com

Understanding the follower window – Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 239

background image

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

241

Configuring the Kinetix 3 Drive Chapter 5

Understanding the Follower
Window

The Properties window for Followers looks like this.

Use the Follower window to configure preset gear ratios and associated cut-off
frequencies.

Follower parameters control drive operation when the Operating Mode is set to
one of these options in the Kinetix 3 Drive window.

Follower: Auxiliary Encoder

Follower: Step / Direction

Follower: Step Up / Step Down

Preset Select 2 = 4 if active, 0 if not.

The Follower window has no associated statuses. The Follower window has these
parameters, and direct commands.

Parameter

Description

Command Type

Select:
Auxiliary Encoder: A quadrature encoder provides a position

command signal input to the drive.

Step/Direction: Step and Direction inputs provide a position

command signal input to the drive.

Step Up/Step Down: Step Up and Step Down inputs provide a

position command signal input to the drive

Controller Output Type

The host controller output type from these options:
Line Drive Input: The controller has differential TTL/CMOS

outputs. The maximum input frequency is 900 kpps.

Open Collector Input: The controller has single-ended

transistor outputs. The maximum input frequency is 300 kpps.

High Frequency Line Driver Input: The controller has

differential TTL/CMOS outputs. The maximum input
frequency is 3.0 mpps.

1st Gear Ratio Change

The time when a gear ratio value will change.
Enable Only on Drive Disabled
Always Enable