Understanding the follower window – Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual
Page 239
Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
241
Configuring the Kinetix 3 Drive Chapter 5
Understanding the Follower
Window
The Properties window for Followers looks like this.
Use the Follower window to configure preset gear ratios and associated cut-off
frequencies.
Follower parameters control drive operation when the Operating Mode is set to
one of these options in the Kinetix 3 Drive window.
•
Follower: Auxiliary Encoder
•
Follower: Step / Direction
•
Follower: Step Up / Step Down
•
Preset Select 2 = 4 if active, 0 if not.
The Follower window has no associated statuses. The Follower window has these
parameters, and direct commands.
Parameter
Description
Command Type
Select:
• Auxiliary Encoder: A quadrature encoder provides a position
command signal input to the drive.
• Step/Direction: Step and Direction inputs provide a position
command signal input to the drive.
• Step Up/Step Down: Step Up and Step Down inputs provide a
position command signal input to the drive
Controller Output Type
The host controller output type from these options:
• Line Drive Input: The controller has differential TTL/CMOS
outputs. The maximum input frequency is 900 kpps.
• Open Collector Input: The controller has single-ended
transistor outputs. The maximum input frequency is 300 kpps.
• High Frequency Line Driver Input: The controller has
differential TTL/CMOS outputs. The maximum input
frequency is 3.0 mpps.
1st Gear Ratio Change
The time when a gear ratio value will change.
• Enable Only on Drive Disabled
• Always Enable