B. Reference – Festo Handling and Positioning Profile (FHPP)
B-50
Festo P.BE-MTR-DCI-CO-EN en 1209a
Drive Data
FHPP
1026
1...8
Array
uint32
rw
Description
General Drive Data
Output stage temp. 1026
1 (CI: 01h)
uint32
rw
Temperature of the end stage in °C. Value range: 0 ... 85
Output stage
Max. temp.
1026
2 (CI:02h)
uint32
rw
Maximum temperature of the end stage in °C. fixed: 80 (0x0050)
Rated motor
current
1026
3 (CI: 03h)
uint32
rw
Nominal motor current in [mA]
Value is automatically entered when an axis type is selected (PNU 1005/4).
Current limit 1026
4 (CI: 04h)
uint32
rw
Max. motor current in permil of rated current. Identical to PNU 1034.
Value range: 1...2000
Lower current limit 1026
5 (CI: 05h)
uint32
rw
= PNU1026.4 * (-1)
Device control 1026
6 (CI: 06h)
uint32
rw
Setting the device control (see PNU 125 / object 207Dh).
0: Control via HMI (control panel) or FCT, no control via fieldbus
1: Control via fieldbus – control interface (default)
Controller serial
number
1026
7 (CI: 07h)
uint32
rw
Serial number of the controller in format 0xDDMYYSSS:
DD (Day):
8 bits:
0x01...0x1F
M (month):
4 bits:
0x1...0xC
YY (Year):
8 bits:
0x00...0x63
SSS (serial number):
12 bits:
0x001...0xFFF
Following error
(permissible con-
touring error)
1026
8 (CI: 08h)
uint32
rw
Following error monitoring