5. Commissioning
5-76
Festo P.BE-MTR-DCI-CO-EN en 1209a
Overview of parameters involved (see section B.2.9)
Parameters involved
Description
FCT
PNU
CO/CI
Nominal values for
positioning mode
Max. permitted speed
1)
x
502
21F6/00h
Direct mode acceleration in acceleration unit
(inc/s
2
)
x
541
20EE/22h
Start
(FHPP control byte)
CPOS.B1 = positive edge: Start
(CDIR.B0 = nominal position absolute/relative)
Reply message
(FHPP status byte)
SPOS.B2 = 0: Motion Complete
SPOS.B1 = positive edge: Quit Start
SPOS.B4 = 1: Drive moves
Requirement
Device control by PLC/field bus
Controller must be in status “Operation enabled”
1)
In the output data the master transfers a percent value which is multiplied by the maximum
permitted speed, in order to achieve the final nominal speed.
Tab. 5/21: Parameters involved in Direct mode (positioning mode)
Power operation
Power operation is used in the following situations:
–
For clamping and holding work items as well as for pro-
cedures in which work items must be orientated (e. g. on
a fixed stop).
–
Pressing and inserting procedures.
–
Special functions in which e. g. work items must be
touched in order to receive position values.