B.2.10 Project data – Power operation
Stroke limit
FHPP
510
–
–
uint32
rw
Description
Maximum permitted stroke with active force control. With active force control, the
actual position relative to the start position must not change by more than the
amount specified in this parameter. In this way you can ensure that, if force control
is activated by mistake (e. g. missing work item), the axis will not perform an un-
controlled movement. This parameter is taken into account in all control modes in
which the position controller is not active in the status “Operation enabled.”
Monitoring can be deactivated when bit RCB1.B5 is set.
Value range: 0...4,294,967,295 Inc
CANopen / CI
60F6h
01h
uint32
rw
Min. Torque (min. permitted force/torque)
FHPP
511
–
–
uint16
rw
Description
This value represents the lowest permitted torque (force) of the motor. The
value is specified in 1/1000 of the rated torque (6076h / PNU 509).
Value range: 0...1000 (0x03E8).
CI access
60F6h
05h
uint16
rw
Max. Torque (max. permitted force/torque)
FHPP
512
–
Var
uint16
rw
Description
This value represents the highest permitted torque (force) of the motor. The
value is specified in 1/1000 of the rated torque (6076h / PNU 509).
Value range: 0...1000 (0x03E8).
CANopen / CI
6072h
– / 00h
Var
uint16
rw