2 procedure – Festo Электромотор MTR-DCI User Manual
Page 126

5. Commissioning
5-28
Festo P.BE-MTR-DCI-CO-EN en 1209a
5.3.2
Procedure
Start the FCT
1. Connect the MTR-DCI to your PC via the RS232 interface.
Follow the instructions in chapter 3.4.
2. Start the FCT:
Double click on the FCT icon on the desktop
– or –
switch to the Windows menu [Start] and select the entry
[Festo Software] [Festo Configuration Tool].
3. Create a project in the FCT or open an existing project.
Add a device to the project with the PlugIn MTR-DCI.
4. Create the device connection (online connection) between
the PC and the MTR-DCI via the FCT tool bar. If necessary,
the device names must be the same.
Device control
In order that the FCT can control the connected MTR-DCI,
the control interface of the MTR-DCI must be deactivated and
“Controller enable” for the FCT must be set (FCT/HMI=On).
The actual status of the control bit ENABLE then has no effect.
•
Switch to the window “Project output” and the register
“Operate.” Then under “Device control” activate first the
box “FCT/HMI” and then the box “Enable.”
The control interface of the MTR-DCI will then be deacti-
vated and Control Enable will be set by the FCT.