7 examples of the i/o data, Safeguard device control, Commissioning 5-49 – Festo Электромотор MTR-DCI User Manual
Page 147: Step/ description output data input data

5. Commissioning
5-49
Festo P.BE-MTR-DCI-CO-EN en 1209a
5.5.7
Examples of the I/O data
On the following pages you will find typical examples of the
I/O data as per FHPP Standard.
1. Record select: Create readiness to operate
2. Direct mode Create readiness to operate
3. Error treatment
4. Homing
5. Record select: Positioning mode
6. Direct mode Positioning mode
7. Direct mode Power operation
A description of the status machine of the MTR-DCI can be
found in section B.3.
Safeguard device control
Step/
Description
Output data
Input data
Byte
B7 B6
B5 B4
B3 B2 B1
B0
Byte
B7 B6 B5 B4 B3 B2 B1 B0
0.1 device control
HMI = on
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
E
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
E
CCON
0
0
0
0
0
x
0
0
SCON
0
0
1
1
0
0
0
0
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HOLD
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HOLD
CPOS
0
0
0
0
0
0
0
0
SPOS
0
0
0
0
0
1
0
0
0: 0-signal
1: 1-signal;
x: not relevant (optional);
F: Edge positive
Tab. 5/7: I/O data “Device control active”
Device control via the control panel or the Festo Configuration
Tool is activated. To control the MTR-DCI via the CANopen in-
terface, device control must first be deactivated by FCT/MMI.