B. Reference – Festo Handling and Positioning Profile (FHPP)
B-40
Festo P.BE-MTR-DCI-CO-EN en 1209a
B.2.14 Project data – Direct mode (power operation)
Force Target window
FHPP
552
–
–
uint16
rw
Description
This is the amount by which the actual force (actual torque) may differ from the
nominal force (nominal torque), in order to be interpreted as still being in the
target window. The width of the window is twice the value transferred, with the
target position in the centre of the window.
The value is specified in 1/1000 of the rated torque (6076h / PNU 509).
Value range: 0...65535. Default: 100.
CANopen / CI
60F6h
03h
uint16
rw
Damping Time
FHPP
553
–
–
uint16
rw
Description
If the actual force (actual torque) has been in the target window this amount of
time, the “Target reached” bit will be set in the status word (Motion Complete).
Value range: 0...30000 ms. Default: 100 ms
CANopen / CI
60F6h
04h
uint16
rw
Speed Limit
FHPP
554
–
–
uint32
rw
Description
Maximum permitted speed with active force control.
In this way you can ensure that, if force control is activated by mistake
(e. g. work item missing), the axis will not undergo uncontrolled acceleration
and move at high speed against a stop.
This parameter is taken into account in all control modes in which the position
controller is not active in the status “Operation enabled.”
Value range: 1...4,294,967,295 inc/s
CANopen / CI
60F6h
02h
uint32
rw