3 operating procedure – IAI America RCM-101-USB User Manual
Page 250

13. Frequency
Analysis Function for SCON-CA
Controller
Anti-V
ibration Control
238
13.3 Operating Procedure
Perform operations according to the procedure specified below.
(1) Select measurement data.
[1] Click the
Parameter (P) menu, point to Control Parameter Setup (C), and then select Frequency
Analysis for Vibration Control (F).
[2] When the “measurement data selection” window appears, select the type of measurement data to be
imported in the “measurement data display/analysis details setting/analysis result display” window under
the frequency analysis for vibration control function.
Fig. 13.43 Measurement Data Selection (“Import New Controller Data” Selected)
[3] If “Import new controller data” has been selected, select the axis number under which to set the load
vibration frequency, and then click the
OK button. If any other option has been selected, select the file to
be read and click the
OK button, and the “frequency analysis for vibration control” window will appear. If
the
Cancel button is clicked, the “frequency analysis for vibration control” window does not appear and
the “measurement data selection” window closes.
(Note) If “Read external measurement data file” or “Read analytical already data file” has been selected,
measurement data cannot be imported from the controller. If you want to import measurement
data from the controller, select “Import new controller data.”
In the “sampling” window or “FFT analysis result” window opened by the aforementioned step, save the
data type currently selected. This way, the saved data type will be automatically selected the next time
the “measurement data selection” window opens.
If “Import new controller data” is selected for the data type currently saved, but the PC software
connection status does not permit selection of “Import new controller data,” “Read external measurement
data file” will be selected.
(Note) The default value of “Import new controller data” is selected immediately after the PC software
has been installed.
[1] Import new controller data
[2] Read external measurement data file
[3] Read analytical already data file