8. Monitoring

108

[Number of channels]

The number of channels is 4 or 8.

A desired number can be selected using user parameter No. 112, “Monitoring mode selection.”

(Setting: “0” = 0 channel (This function is not used), “1” = 4 channels, “2” = 8 channels)

[Buffering period]

For the buffering period, a desired value between 1 and 100 [msec] can be set using user parameter

No. 113, “Buffering period.” (Setting: “1” to “100” [msec])

[Number of records that can be monitored]

When the SCON-CA, the number of records that can be monitored is 30,000 in the 4-channel mode

and 15,000 in the 8-channel mode.

When the MSCON, the number of records that can be monitored is 30,000 in the 2-channel mode,

15,000 in the 4-channel mode and 7,500 in the 8-channel mode.

When the PCON-CA and ERC3, the number of records that can be monitored is 1,500 in the

4-channel mode and 7,500 in the 8-channel mode.