beautypg.com

Avago Technologies LSI SAS 3041E-R User Manual

Page 50

background image

3-10

UNIX Operating System Device Drivers

Version 1.3

Copyright © 2001, 2002, 2007 by LSI Logic Corporation. All rights reserved.

4.

If the LSI host adapter is not listed, shut down the system and be
sure that the host adapter is firmly seated in the slot and is
connected properly. Check the diagrams and instructions in the host
adapter user’s guide. Some LSI adapters include the string LSILogic
and others, such as the example above, include IntraServer. Both are
valid LSI products.

To determine if all SCSI, SAS, and/or Fibre Channel disk drives are
properly connected and functional, use the

probe-scsi-all

command

at the

ok

prompt. The system displays output similar to the following:

/pci@1f,0/pci@1/IntraServer,Ultra2-scsi@1

Target 0

Unit 0 Disk IBM DNES-309170W SA30

/pci@1f,0/pci@1/pci@2/IntraServer,fc@7
MPT Firmware Version 1.00
Target 0

Unit 0 Disk SEAGATE ST39173FC 6615
WWN 220000203710d063 ID 111d2

Target 1

Unit 0 Disk SEAGATE ST39173FC 6258
WWN 220000203710c09b ID 111d6

Target 2

Unit 0 Disk SEAGATE ST39173FC 6258
WWN 220000203710b066 ID 111d5

Target 3

Unit 0 Disk SEAGATE ST39173FC 6258
WWN 220000203710b063 ID 111d3

Target 4

Unit 0 Disk SEAGATE ST39173FC 6258
WWN 220000203710b04f ID 111d4

Target 5

Unit 0 Disk SEAGATE ST39173FC 6615
WWN 2200002037104f73 ID 111d9

Target 6

Unit 0 Disk SEAGATE ST39173FC 6615
WWN 2200002037102d0f ID 111d1

If some of the disk drives connected to the host adapter(s) are not listed
in this display, check the following:

Are all the cables correctly connected to the disk enclosure?

Is the disk enclosure powered up?

If the external disk enclosure requires a loopback connector, is the