beautypg.com

Avago Technologies LSI SAS 3041E-R User Manual

Page 109

background image

CFGGEN Commands

6-11

Version 1.3

Copyright © 2001, 2002, 2007 by LSI Logic Corporation. All rights reserved.

Parameters –

– Number of the SCSI bus or SAS controller targeted
by this command.

[filename] – Optional valid filename to store output of command to a
file.

Program Return Value –

0x00

SUCCESS: Command completed successfully.

0x01

FAILURE: Bad command line arguments or operational failure.

0x02

ADAPTER_NOT_FOUND: Specified adapter cannot be found.

Sample Output –

The following example shows the output of the DISPLAY command for
an IM configuration on a SAS1068 controller.

Note:

The format and content of the DISPLAY command output
varies, depending on the CFGGEN version being used.

Read configuration has been initiated for controller 0
------------------------------------------------------------
Controller information
------------------------------------------------------------
Controller type

: SAS1068

BIOS version

: 6.xx.xx.00

Firmware version

: 0.09.03.219

Channel description

: 1 Serial Attached SCSI

Initiator ID

: 63

Maximum physical devices

: 62

Concurrent commands supported

: 511

Slot

: 6

Bus

: 3

Device

: 1

Function

: 0

RAID Support

: Yes

------------------------------------------------------------
IR Volume information
------------------------------------------------------------
IR volume 1
Volume ID

: 7

Status of volume

: Okay (OKY)

RAID level

: 1

Size (in MB)

: 34332

Physical hard disks (Target ID)

: 11 8