The FORMAT command does not complete and return to a shell prompt
until the format operation is complete. This may take a long time for a
large disk drive.

Command Line –

cfggen format [noprompt]

cfggen format [noprompt]

Parameters –

– Number of the controller targeted by this command.

– SCSI ID of the hard disk drive to be formatted.

– The enclosure:bay value for the disk drive to be
formatted. These values can be obtained from the output of the
DISPLAY command.

noprompt – Suppresses display of warnings and prompts.

Program Return Value –

0x00

SUCCESS: Command completed successfully.

0x01

FAILURE: Bad command line arguments or operational failure.

0x02

ADAPTER_NOT_FOUND: Specified adapter cannot be found.

6.3.9

HOTSPARE Command

The HOTSPARE command creates a hot spare disk drive, which is
added to hot spare pool 0. The number of disk drives in an IM, IME, or
IS volume, including the hot spare disk, cannot exceed six for
LSI53C1020/1030 controllers or eight for LSI1064/1064E and
LSI1068/1068E controllers. Only one hot spare disk can be created.

The capacity of the hot spare disk must be greater than or equal to the
capacity of the smallest disk in the logical drive. An easy way to verify
this is to use the DISPLAY command.

The following rules must be observed when creating hot spare disks:

1.

A hot spare disk cannot be created unless at least one IM or IME
volume is already created.