Table 8.6

shows the possible values for the Status field.

Array Disk

Indicates if the disk drive is part of an array. If Yes, it is; if No, it is not. The field is
grayed out if any of the following is true:

The disk drive does not meet the minimum requirements for use in a RAID array.

The disk drive is not large enough to mirror existing data.

The disk drive has been configured as a hot spare.

The array already has the maximum number of disk drives.

Hot Spare

Indicates if the disk drive is a hot spare for a RAID array. If Yes, it is; if No, it is not.
IM and RAID 1E arrays can have one optional hot spare each. Hot spares can be
created when the array is created or can be added later. RAID 1E arrays with a hot
spare disk can have a maximum of 5 disk drive members, plus the hot spare drive.
The Hot Spare field is grayed out if any of the following is true:

The disk drive does not meet the minimum requirements for use in a RAID array.

The disk drive is not large enough to mirror existing data on the primary drive.

Integrated Striping firmware is being used. (IS arrays cannot use hot spares.)

Status

Current status of disks that are part of a RAID array.

Table 8.6

lists the possible

entries.

Predict Failure

Indicates whether SMART is predicting that the disk drive will fail.

Size (MB)

Indicates the size of the disk drive, in megabytes. If the disk drive is part of a 2-disk
array, this field indicates the size of the array, not the size of the individual disk. If
the disk drive is part of an array with 3 or more disk drives, this field indicates the
size that the disk makes up within the array.

Table 8.5

RAID Properties Field Descriptions (Cont.)

Field

Description

Table 8.6

Status Field Definitions

Status

Definition

Ok

Disk is online and fully functional

Missing

Disk is not responding

Failed

Disk has failed

Initing

Disk is initializing

CfgOffline

Disk is offline at host’s request

UserFailed

Disk is marked failed at host’s request

Offline

Disk is offline for some other reason

Inactive

Disk has been set inactive

Out of Sync

Data on disk is not synchronized with the rest of the array

Primary

Disk is the primary disk for a 2-disk mirrored array and is OK

Secondary

Disk is the secondary disk for a 2-disk mirrored array and is OK