Allied Telesis AlliedView-EMS 4.0.1 DEVICE MANAGEMENT User Manual
Page 91
Note
- Ports are numbered continuously from top to bottom, across all installed line cards,
starting from the leftmost line card all the way through the rightmost line card. This applies
to the following submenu options:
Utilization
Interface Info -> Standard
Error Statistics -> Standard
Spanning Tree Info
Utilization
Displays the port's utilization information.
Interface Info
Displays port statistics such as the number of frames received and transmitted on
the port, bytes received and transmitted on the port, and port status.
Note
- Valid MIB Set values for the Administration Status parameter are 'up' and
'down'. Attempting to set this parameter to any other value will result in the error
message: "The error occurred with 'Set' operation. Error: bad value.".
Error Statistics
Displays error statistics such as alignment error frames and carrier sense errors.
Detail Info
Displays detailed port information such as duplex mode.
Note
- The current firmware version does not allow the Port Name parameter to be
set to NULL. Attempting to set this parameter to NULL will result in the error
message: "The error occurred with 'Set' operation. Error: bad value.".
Spanning Tree Info
Displays the port's spanning tree parameters.
Note
- The current firmware version does not allow the Port parameter to be
configured. Attempting to configure this parameter will result in the error message:
"The error occurred with 'Set' operation. Error: readOnly".
Port Security
Displays the port security attributes for each physical port present in the switch.
Enable
Enables the port.
Disable
Disables the port.
Port Mirroring
AlliedView™-EMS 4.0.1 Device Management Guide
Page 91 of 411