Allied Telesis AlliedView-EMS 4.0.1 DEVICE MANAGEMENT User Manual
Page 237
![background image](/manuals/427390/237/background.png)
Note
- When multiple units of the AT-9400 are stacked together, the current
firmware version will always return the value '1' for the Number of Modules
parameter.
Device Info
General Info
Displays general information about the switch.
Note
- L2+ Models: The current firmware version returns an incorrect value for the
RPS Present parameter. If the device is connected to an RPS, the RPS Present
parameter returns 'disconnected'. If it is not, it returns 'connected'.
Note
- The current firmware version does not return the correct value for the
Hardware Version parameter of the following models:
AT-9408LC/SP
AT-9424T/GB
AT-9424T/SP
AT-9424Ts
Note
- AT-9424T & AT-9424T/POE: The current firmware version always returns
the value 'on' for the RPS State parameter regardless of its current state.
Uplink Info
Displays uplink information.
Note
- AT-94xxTs/XP: The current firmware version does not return the Uplink Info
of the XFP port slots with XFP module/s inserted.
Note
- AT-9448Ts/XP: When multiple units of the AT-9400 are stacked together,
the current firmware version intermittently returns values for non-uplink ports or
does not return any values for the Uplink Info parameter.
Temperature Info
Displays temperature information.
Note
- This table is applicable to the L2+ models only.
Fan Info
Displays fan information.
Note
- This table is applicable to the L2+ models only.
Note
- AT-9424T/POE: The current firmware version returns a 'noSuchName' value
for the Fan Info parameter.
AlliedView™-EMS 4.0.1 Device Management Guide
Page 237 of 411