Allied Telesis AlliedView-EMS 4.0.1 DEVICE MANAGEMENT User Manual
Page 53

valid value will result in the error "The error occurred with 'Set' operation. Error.
bad value.".
POE Port Status
Displays port's POE information.
Note
- Valid MIB Set values for the Port Power Limit parameter is [0 - 2147483647].
However, the current firmware version does not allow this parameter to be
configured to any value. Attempting to configure this parameter from 15401-
2147483647 will result in the error "The error occurred with 'Set' operation.Error:
gen error".
Spanning Tree Info
STP
Standard
Displays the port's spanning tree parameters.
Additional Info
Displays a list of information maintained by every port about the Spanning
Tree Protocol state for that port.
Note
- The current firmware version does not allow Device Manager to
handle 'TruthValues' for the following parameters:
Dampening Enable
Filter BPDU
Restricted Role
Auto Edge Port
As a result, Device Manager will display integer values of '1' and '2' instead of
the value 'True' or 'False' for these parameters.
MSTP
MSTI
Displays a list of information maintained by every pair
Spanning Tree Protocol state for that pair.
CIST
Displays a list of information maintained by every port of the CIST.
Enable
Enables the port.
Disable
Disables the port.
Port Lock
Basic Info
AlliedView™-EMS 4.0.1 Device Management Guide