Allied Telesis AlliedView-EMS 4.0.1 DEVICE MANAGEMENT User Manual
Page 53
![background image](/manuals/427390/53/background.png)
valid value will result in the error "The error occurred with 'Set' operation. Error.
bad value.".
POE Port Status
Displays port's POE information.
Note
- Valid MIB Set values for the Port Power Limit parameter is [0 - 2147483647].
However, the current firmware version does not allow this parameter to be
configured to any value. Attempting to configure this parameter from 15401-
2147483647 will result in the error "The error occurred with 'Set' operation.Error:
gen error".
Spanning Tree Info
STP
Standard
Displays the port's spanning tree parameters.
Additional Info
Displays a list of information maintained by every port about the Spanning
Tree Protocol state for that port.
Note
- The current firmware version does not allow Device Manager to
handle 'TruthValues' for the following parameters:
Dampening Enable
Filter BPDU
Restricted Role
Auto Edge Port
As a result, Device Manager will display integer values of '1' and '2' instead of
the value 'True' or 'False' for these parameters.
MSTP
MSTI
Displays a list of information maintained by every pair
Spanning Tree Protocol state for that pair.
CIST
Displays a list of information maintained by every port of the CIST.
Enable
Enables the port.
Disable
Disables the port.
Port Lock
Basic Info
AlliedView™-EMS 4.0.1 Device Management Guide