Error Statistics
Displays error statistics.
Note
- The Ethernet Chipset parameter is not applicable to the AT-x900-24X series
(AlliedWare Plus) and should be ignored.
Received Address
Displays the address for which the system will accept packets/frames on the
particular interface.
Note
- The Received Address parameter is not applicable to the AT-x900-24X series
(AlliedWare Plus) and should be ignored
Note
- The Received Address Status and Received Address Type parameters are
implemented as 'read-only'.
Spanning Tree Info
Standard
Displays the port's spanning tree parameters.
Note
- Valid MIB Set values for the Port Path Cost parameter is in the range [1-
65535] inclusive.
Note
- The current firmware version does not allow the Port parameter to be
configured.
Additional Info
Displays additional information on the port's spanning tree parameters.
Note
- The current firmware version does not allow the Protocol Migration
parameter to be set to 'true'.
Note
- The current firmware version does not allow the Point-to-Point Config
parameter to be set to 'auto'.
Note
- Valid MIB Set values for the Port Path Cost Config parameter is [1-
200000000] inclusive. However, the current firmware version allows the user to set
this parameter to '0' as its value and will automatically set the entered value to valid
values.
MAC Control Pause
Displays information about the MAC Control Pause function on a single ethernet-
like interface.
Note
- The current firmware version returns a 'noSuchName' value for the Received
Frames (HC) and Transmit Frames (HC) parameters.
Note
- The PAUSE Config parameter is implemented as 'read-only'.
AlliedView™-EMS 4.0.1 Device Management Guide
Page 351 of 411