beautypg.com

Allied Telesis AlliedView-EMS 4.0.1 DEVICE MANAGEMENT User Manual

Page 297

background image



Trigger

Trigger Info

Displays the trigger configuration information in the device.

Trigger Counters

Displays counters in activation of the triggers in the device.


Remote Ping

Ping Objects

Displays the maximum number of concurrent active ping requests.

Note

- The Target Address Type parameter is implemented as 'read-only'.

Ping Control

Defines the Ping Control Table for providing, via SNMP, the capability of performing

ping operations at a remote host.

Note

- The current firmware version returns a 'noSuchName' value for the Owner

Index and Test Name parameters.

Note

- Device Manager does not handle MIB table with Read-Create access

correctly. Attempting to set any parameters of this table will result in the error "The

Error occurred with 'Set' operation.Error:NoSuchname".

Ping Results

Displays the results of the performed ping operations in the Ping Control table.

Note

- Device Manager does not handle objects of type OCTET STRING correctly.

As a result, the Target IP Address parameter will display a sequence of bytes in

hexadecimal format instead of the actual IP address of the remote host.

Note

- Device Manager does not handle objects of type OCTET STRING correctly.

As a result, the Last Good Probe parameter will display a sequence of bytes in

hexadecimal format instead of the actual date and time of day.

Ping Probe History Table

Displays ping probe history in performing ping operations.

Note

- The current firmware version returns a 'noSuchName' value for the Ping

Probe History Table parameters.