Device Manager LEDs for Rapiers
LED
State
Description
PWR Green
Red
The switch is receiving power from the main power supply.
The main power supply has failed.
RPS Green
Red
Gray
The switch is receiving power from the redundant power supply.
RPS has failed.
RPS is not installed or RPS monitoring is disabled.
DUPLEX Green
Orange
The port is operating at full duplex.
The port is operating at half duplex.
Note
- The current firmware version does not allow Device Manager to support the Reset
button.
Note
- Please refer to Uplink Modules for the operations and behavior of the uplink
modules installed in these devices.
Note
- Please refer to Network Service Modules for the operations and behavior of the
Network Service Modules installed in these devices.
Note
- To turn RPS monitoring on or off on the switch, enter the command SET SYSTEM
RPSMONITOR={ON|OFF} from the command line interface. To see whether RPS
monitoring is on, use the command SHOW SYSTEM. To turn on RPS monitoring using
SNMP, set the fanAndPsRpsMonitoringStatus variable to on.
Agent Menu
From the Agent menu, you can view and edit the system information for the switch, or log
into the CLI using Telnet.
System Info
Displays basic system information, including system name, location, contact and
description.
Power Supply Info
Displays information about the power supply, redundant power supply and power
supply monitoring.
File List
Displays a list of the files in the switch's file system.
Config File Name
Displays the file name of the start-up configuration file.
AlliedView™-EMS 4.0.1 Device Management Guide