beautypg.com

Caution – GW Instek APS-1102 User Manual User Manual

Page 88

background image

4.4 Using the Sequence Function

APS-1102 Programmable AC/DC Power Source

4-24

An example of basic step transitions is shown below.

Output parameters

Time

Normal output

step

Step 1

Step 2

Step 3

Steps 1, 2

Step 3

Figure 4-5. Example of Basic Step Transitions

c) Sequence mode

Figure 4-6 shows a mode transition diagram for sequence operations.

Idle mode

(normal output)

Output on

Run mode
(sequence
execution)

Hold mode

(pause)

Figure 4-6. Block Diagram of Sequence Mode Transitions

Modes also change according to the [step end] specification.

Table 4-6. Sequence Modes

Idle mode

Mode during normal output.

Run mode

Mode during sequence execution.

Hold mode

Sequence pause mode.
Maintains output at time when was set.

CAUTION