6.2 Command List

APS-1102 Programmable AC/DC Power Source

6-4

Table 6-2. Command List (MEASure Subsystem)

Function Command

Output current RMS value

MEASure[:SCALar]:CURRent[:AC]?

+ current peak value

MEASure[:SCALar]:CURRent:HIGH?

 current peak value

MEASure[:SCALar]:CURRent:LOW?

Output current peak value hold

MEASure[:SCALar]:CURRent:AMPLitude:MAX?

Output current peak value hold reset

MEASure[:SCALar]:CURRent:AMPLitude:RESet?

Output current average value

MEASure[:SCALar]:CURRent:AVErage?

Load crest factor

MEASure[:SCALar]:CURRent:CREStfactor?

Output harmonic current [Arms]

MEASure[:SCALar]:CURRent:HARMonic[:AMPLitude]?

Output harmonic current [%]

MEASure[:SCALar]:CURRent:HARMonic:RATio?

External input signal frequency

MEASure[:SCALar]:FREQuency?

Apparent power

MEASure[:SCALar]:POWer:AC:APParent?

Output power factor

MEASure[:SCALar]:POWer:AC:PFACtor?

Reactive power

MEASure[:SCALar]:POWer:AC:REACtive?

Effective power

MEASure[:SCALar]:POWer:AC[:REAL]?

Output voltage RMS value

MEASure[:SCALar]:VOLTage[:AC]?

+ voltage peak value

MEASure[:SCALar]:VOLTage:HIGH?

 voltage peak value

MEASure[:SCALar]:VOLTage:LOW?

Output voltage average value

MEASure[:SCALar]:VOLTage:AVErage?

Table 6-3. Command List (DISPlay Subsystem)

Function Command

Select measurement display

DISPlay[:WINDow]:MEASure:MODE