2.2 Installation Environment

APS-1102 Programmable AC/DC Power Source

2-4

Conditions of installation site

The APS-1102 should be used indoors, and at an elevation of 2,000 meters.

The APS-1102 uses a fan for forced-air cooling. To allow for ample air flow, be sure to
maintain a gap of at least 50 cm between the air inlets and outlets along the sides and rear of
this product and walls or other obstructions.

Install this product in a location that meets the following conditions for temperature and
humidity ranges.

Operation

guarantee

0°C to +40°C

5 to 85%RH
Absolute humidity of 1 to 25 g/m

3

, no condensation.

Performance

guarantee

+5°C to +35°C

5 to 85%RH
Absolute humidity of 1 to 25 g/m

3

, no condensation.

Storage

condition

10°C to +50°C

5 to 95%RH
Absolute humidity of 1 to 29 g/m

3

, no condensation.

Product reliability may decline in extreme temperature and/or humidity environments. An
environment of approximately 25°C and 50%RH is recommended.
Figure 2-1 illustrates these ambient temperature and humidity ranges.

10 0 10 20 30 40 50

C

Performance

guarantee

%RH

90

80

70

60

50

40

30

20

10

0

Storage

condition

Operation

guarantee

Figure 2-1. Ambient Temperature and Humidity Ranges