beautypg.com

GW Instek APS-1102 User Manual User Manual

Page 233

background image

7.2 Error Messages and Responses

APS-1102 Programmable AC/DC Power Source

7-11

Protection Function”.)

Figure 7-4. Screen Display When Warning Has Occurred


Until the warning has been canceled for the device, no key or command operations will be accepted.
When the warning is canceled for the device, “Press ENTER key” is displayed on the warning screen. To
close the warning screen, press the ENTER key or CANCEL key. If the “Press ENTER key.” message is
not shown within 10 seconds, turn off the power and turn it on again.
Table 7-6 and Table 7-7 describe these warning messages.

Table 7-6. Warning Messages (1/2)

Message

Cause and Action Required

Output OFF.
caused by:

OVER VOLTAGE

Output off due to the output overvoltage protection function.
Press the ENTER key or CANCEL key. The error is cleared
and the system becomes available. Check settings and load
conditions before using.

Output OFF.
caused by:

OVER CURRENT

Output off due to the output average current protection
function.
Press the ENTER key or CANCEL key. The error is cleared
and the system becomes available. Check settings and load
conditions before using.