beautypg.com

4 setting the output voltage – GW Instek APS-1102 User Manual User Manual

Page 71

background image

4.1 Use as a DC Power Source

APS-1102 Programmable AC/DC Power Source

4-7

4.1.4 Setting the output voltage

The ranges that can be set are listed below.

Table 4-3. Output Voltage Setting Ranges When AC+DC Mode Is Selected

Setting

Setting range

resolution

DC voltage

100 V range

200.0 to +200.0 V

0.1 V

200 V range

400.0 to +400.0 V

0.1 V

AC voltage

100 V range

SIN/SQU

0.0 to 140.0 Vrms

0.1 Vrms

ARB1 to ARB16

0.0 to 400.0 Vp-p

0.1 Vp-p

200 V range

SIN/SQU

0.0 to 280.0 Vrms

0.1 Vrms

ARB1 to ARB16

0.0 to 800.0 Vp-p

0.1 Vp-p

Output can be set so that AC voltage is superimposed on DC voltage.
The unit for AC voltage settings differs according to the AC voltage waveform setting.
When the selected AC voltage waveform is SIN/SQU, the AC voltage setting is in Vrms units, and
when it is ARB1 to ARB16, the setting is in Vp-p units.

To select an output voltage, select

“DC voltage” or

“AC voltage” in the SET menu, then set

a numerical value.

Operation steps

1. Press the

or

key to move the cursor to the

or

icon.

ENTER

CANCEL

Cursor

2. Press the

ENTER

key to display the modification box.

ENTER

CANCEL

Modification box