6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-20

Type

Range

200.0 to 200.0 (400.0 to 400.0)

Second parameter (DC voltage operation type)

Type

Range 0 (CONST), 1 (KEEP), or 2 (SWEEP)

Third parameter (AC voltage [Vrms]/[Vp-p])
* The unit varies according to the waveform set by the seventh parameter.

Type

Range 0.0 to 140.0 [Vrms] or 0.0 to 400.0 [Vp-p]

(0.0 to 280.0 [Vrms] or 0.0 to 800.0 [Vp-p])

Fourth parameter (AC voltage operation type)

Type

Range

0 (CONST), 1 (KEEP), or 2 (SWEEP)

Fifth parameter (frequency)

Type

Range

1.0 to 550.0

Sixth parameter (frequency operation type)

Type

Range

0 (CONST), 1 (KEEP), or 2 (SWEEP)

Seventh

parameter

(waveform)

*The unit for the third parameter AC voltage varies depending on the seventh parameter
setting.

Type

Range

0 (SIN), 1 (SQU), or 2 to 17 (ARB1 to ARB16)

Eighth parameter (waveform operation type)

Type

Range

0 (CONST) or 1 (KEEP)

Ninth parameter (start phase)

Type

Range

0.0 to 359.9

10th parameter (start phase operation)

Type

Range

0 (CONST) or 1 (KEEP)

11th parameter (step synchronized output)

Type

Range

0 (00), 1 (01), 2 (10), or 3 (11)

12th parameter (step synchronized output operation type)

Type

Range

0 (CONST) or 1 (KEEP)

Command example: SEQ:EPAR 0, 0, 100.0, 0, 50.0, 0, 1, 0, 90.0, 0, 0, 0
Query

example: SEQ:EPAR?

Response example: 0, 0, 100.0, 0, 50.0, 0, 1, 0, 90.0, 0, 0, 0