9.5 Measurement Functions

APS-1102 Programmable AC/DC Power Source

9-9

Output power measurement
Effective

power

Full

scale:

1200

W

Display

resolution:

1

W

Measurement accuracy: ±2% of the full scale (at 23 ±5°C)

(when output is 100 VA or above)


Apparent power:

Calculated as output voltage RMS value × output current RMS value

Full

scale:

1400

VA

Display

resolution:

1

VA

Measurement accuracy: ±2% of the full scale (at 23 ±5°C)

(when output is 100 VA or above)


Reactive power:

Calculated as

(apparent power)

2

– (effective power)

2

Full

scale:

1400

Var

Display

resolution:

1

Var

Measurement accuracy: ±2% of the full scale (at 23 ±5°C)

(when output is 100 VA or above)

Load power factor measurement: Calculated as effective power / apparent power

Measurement range:

0.00 to 1.00

Display resolution:

0.01

Load crest factor measurement: Calculated as (

 positive peak current  and  negative

peak current

 maximum value) / RMS current

Measurement range:

0.00 to 50.00

Display resolution:

0.01

Output harmonic current measurement
(AC - INT mode only, fundamental wave is 50 or 60 Hz only)
Measurement range:

To 40th harmonic of fundamental wave

Full scale:

15 Arms and 100%

Display resolution:

0.01 Arms and 0.1%

Measurement accuracy:

1% of full scale at RMS value current (at 23 ±5°C, to 20th harmonic)

±1.5% of full scale at RMS value current (at 23 ±5°C, from 20th to

40th)
Note: This measurement does not comply with the IEC standards.

External synchronization frequency measurement
(external synchronization mode only)
Measurement range:

38.0 to 525.0 Hz

Display resolution:

0.1 Hz

Measurement accuracy:

±0.2 Hz (at 23 ±5°C, 50 or 60 Hz)