9.11 External Control I/O

APS-1102 Programmable AC/DC Power Source

9-13

9.11 External Control I/O

External control operation mode
Enabled or disabled (status output is continually output)

Control input
Input level

High level: +4.0 V or above, Low level: +1.0 V or below

Nondestructive

maximum

input:

+10

V/

5 V

Input impedance

+5 V pull-up with 47 k

Control item

Output off:

Output off at fall

Output on:

Output on at fall

Start sequence:

Start at fall

Stop sequence:

Stop at fall

Hold input:

Hold at fall

Branch inputs 0, 1: Start branch at fall

Status output

Output level

0/+5 V (open)

Output

impedance

100

Status items

Power source on/off status:

0-off, 1-on

Output on/off status:

0-off, 1-on

Limiter operation:

0- Not operating, 1- Operating

Software busy:

0- Normal, 1- Busy

Sequence operation step synchronized outputs 0 and 1

Terminals
D-sub 25-pin multi-connector (rear panel)

9.12 USB Interface

USB interface is provided to enable control from an external computer.
Interface standard: USBTMC

9.13 Power Input

Input voltage range:

100 V AC to 230 V AC ±10% (not exceeding 250 V)

Overvoltage

Category

II

Frequency range:

50 Hz or 60 Hz ±2 Hz (single phase)

Power consumption:

1.4 kVA or less

Power factor:

0.95 or above (during 100 V AC input)

0.90 or above (during 200 V AC input)

Protective ground impedance:

0.1 Ω or less (not including the power cord set)