6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-33

g) OUTPut subsystem

OUTPut[:STATe]
This controls on/off settings of the output relay.

Syntax:

OUTPut[:STATe]

Parameters:

OFF|0 / ON|1

Command example:

OUTP ON

Query

example:

OUTP?

Response format:

Response

example: 1


h) INPut subsystem

INPut:GAIN
This sets the external input gain used in the external mode (AC-EXT or AC+DC-EXT) and
internal + external mode (AC-ADD or AC+DC-ADD). For the 100 V range, the external input
gain setting ranges from 0.0 to 200.0 and for the 200 V range, it ranges from 0.0 to 400.0.
When in AC-EXT, AC-ADD, AC+DC-EXT, or AC+DC-ADD mode, the output waveform setting
cannot be made. ([3, “Invalid in this mode”] error occurs.)

Syntax:

INPut:GAIN

Parameters:

0.0 to 200.0 (0.0 to 400.0)

Command example:

INP:GAIN 10.0

Query

example:

INP:GAIN?

Response format:

Response

example: 10.0