beautypg.com

1 status icons – GW Instek APS-1102 User Manual User Manual

Page 131

background image

5.1 Screen Configuration


APS-1102 Programmable AC/DC Power Source

5-5

5.1.1 Status icons

The status window displays status icons that indicate the status of the APS-1102.
These status icons are listed below in Table 5-1.

Table 5-1. Status Icons List

Icon Item

Description

Battery almost depleted

When a backup memory checksum error occurs, this icon
flashes to indicate that the battery is almost depleted.

Unlock

This icon goes on when external line synchronization is
disabled.

Calibration data
valid/invalid

This icon flashes when the calibration data is invalid
(uncalibrated).

Busy

This icon goes on to indicate busy status.

Limiter operations

These icons are displayed in the same positions on the control
panel. When the limiter operates, the displayed icons change
as shown below.
During peak current limiter operation:

appears.

During average current limiter operation:

appears.

During power limiter operation:

appears.

During voltage peak limiter operation:

appears.

Sequence is being executed

These icons are displayed in the same positions on the control
panel. The displayed icons change as shown below according
to the sequence status.
In Idle mode: Nothing is displayed.
In Run mode:

is displayed.

In Hold mode:

is displayed.

Sequence hold

Keylock

This icon goes on when keylock is on.

Remote

The displayed icons change as shown below according to the
APS-1102 status.
Local:

Nothing is displayed.

Remote:

is displayed.