beautypg.com

GW Instek APS-1102 User Manual User Manual

Page 251

background image

9.1 Output

APS-1102 Programmable AC/DC Power Source

9-3

Output terminals
Terminal block with M4 screws (rear panel)
AC receptacle (universal type, front panel)

Note: Use AC receptacle for AC (0 V AC to 250 V AC). When DC is included, use screw terminal

block on rear panel.

Rated output
100 V range: 100 Vrms (AC) / 100 V (DC)
200 V range: 200 Vrms (AC) / 200 V (DC)

Output voltage settings
(When signal source mode is internal mode or internal + external mode, no load)

Note: The AC settings (peak value)+ DC setting that can be set are within the voltage setting limit

range.

AC
100 V range:

0.0 to 140.0 Vrms

200 V range:

0.0 to 280.0 Vrms

Setting resolution:

0.1 Vrms

Setting accuracy:

±(0.5% of set value +0.6 Vrms): 100 V range

±(0.5% of set value +1.2 Vrms): 200 V range

(AC mode, 50 Hz, 23 ±5°C)

DC
100 V range:

200.0 V to +200.0 V

200

V

range:

400.0 V to +400.0 V

Setting resolution:

0.1 V

Setting

accuracy:

±(

 0.5 % of set value  + 0.8 V): 100 V range

±(

 0.5 % of set value  + 1.6 V): 200 V range

(AC+DC mode, 0 V AC setting, 23 ±5°C)

Maximum output current
100 V range: 10 Arms (AC) / 10 A (DC)
200 V range: 5 Arms (AC) / 5 A (DC)

Note 1:

For the AC 100 V input system, the limit on the maximum output power may cause a
reduction in the maximum output current.

Note 2:

At or above the rated output voltage, the limit on the maximum output power reduces the
maximum output current.

Note 3:

When output frequency is 40 Hz or lower, or it is 400 Hz or higher, the maximum output
current may decrease.

Note 4:

The RMS value for AC + DC is within the maximum output current.