3.3 I/O Terminals

APS-1102 Programmable AC/DC Power Source

3-12

Table 3-3. External Control I/O Connectors

Pin No.

I/O

Function

Remark

1

Output

Power source on/off status

0: Off
1: On

2

Output

Output on/off status

0: Off
1: On

3 Output

Limiter operation

Note

0: Off
1: On

4

Output

Software busy

0: Normal
1: Busy

5

Output

Sequence sync output 0

6

Output

Sequence sync output 1

7 Output

Undefined

8 Output

Undefined

9 GND

10 Input

Undefined

11

Input

Output off

Falling edge detection

12

Input

Output on

Falling edge detection

13

Input

Sequence start

Falling edge detection

14

Input

Sequence stop

Falling edge detection

15

Input

Sequence hold

Falling edge detection

16

Input

Sequence branch trigger 0

Falling edge detection

17

Input

Sequence branch trigger 1

Falling edge detection

18 GND

19

Output

+5 V

50 mA or less

20 Output

Reserved

21 Output

Reserved

22 Output

Reserved

23 Output

Reserved

24 Output

Reserved

25 Output

Reserved

Note When output peak current limiter (positive), output peak current limiter (negative), output

average current limiter, or output power limiter is operated, it is recognized as limiter
operation on.

External control input and output can be used when external control has been set as enabled.