9.5 Measurement Functions

APS-1102 Programmable AC/DC Power Source

9-8

9.5 Measurement Functions

Output voltage measurement
RMS value:

RMS value of AC+DC

Full scale:

225.0 Vrms: 100 V range

450.0 Vrms: 200 V range

Display

resolution:

0.1

Vrms

Measurement accuracy: ±0.5% of the full scale (at 23 ±5°C)

Average value:

Average value of AC+DC (measures DC component)

Full scale:

±225.0 V: 100 V range

±450.0

V:

200

V

range

Display

resolution:

0.1

V

Measurement accuracy: ±0.5% of the full scale (at 23 ±5°C)

Peak value:

Positive peak voltage and negative peak voltage are displayed

separately

Full scale:

+225 Vpk /

225 Vpk: 100 V range

+450 Vpk /

450 Vpk: 200 V range

Display

resolution:

1

Vpk

Measurement accuracy: ±3% of the full scale (at 23 ±5°C, sine wave)

Output current measurement
RMS value:

RMS value of AC+DC

Full

scale:

15.00

Arms

Display

resolution:

0.01

Arms

Measurement accuracy: ±1.0% of the full scale (at 23 ±5°C)

Average value:

Average value of AC+DC (measures DC component)

Full

scale:

±15.00

A

Display

resolution:

0.01

A

Measurement accuracy: ±1.0% of the full scale (at 23 ±5°C)

Peak value:

Positive peak current and negative peak current are displayed

separately

Full scale:

+45.0 Apk /

45.0 Apk

Display

resolution:

0.1

Apk

Measurement accuracy: ±3% of the full scale (at 23 ±5°C, sine wave)

Peak value hold:

 + peak current  and   peak current |maximum value

Full

scale:

45.0

Apk

Display

resolution:

0.1

Apk

Measurement

accuracy:

3% of the full scale (at 23 5°C, sine wave)