6.3 Command Descriptions
APS-1102 Programmable AC/DC Power Source
6-35
TRACe:DELete[:NAME]
This clears the specified arbitrary waveform memory. When this command is executed, a sine
wave is written to ARB1 to ARB8, a square wave is written to ARB9 to ARB12, and a triangle
wave is written to ARB13 to ARB16.
However, when output is on, the arbitrary waveform memory cannot be cleared. ([1, “Invalid with
output on”] error occurs.)
Syntax:
TRACe:DELete[:NAME]
Parameters:
ARB1 to ARB16
Command example:
TRAC:DEL ARB1
Response format:
None
Response example:
None
j) SYSTem subsystem
SYSTem:BEEPer:STATe
This controls the beep on/off setting. When the beep sound is enabled, beeps accompanying
cursor operations become enabled, and an operation error or a protected operation will be notified
with a beep.
Syntax:
SYSTem:BEEPer:STATe
Parameters:
OFF | 0 / ON | 1
Command example:
SYST:BEEP:STATe ON
Query
example:
SYST:BEEP:STATe?
Response format:
Response
example: 1
SYSTem:CONFigure:EXTIO
This controls the external control input enable/disable setting.
Syntax:
SYSTem:CONFigure:EXTIO
Parameters:
OFF | 0 / ON | 1
Command example:
SYST:CONF:EXTIO ON
Query
example:
SYST:CONF:EXTIO?
Response format:
Response example:
1