beautypg.com

GW Instek APS-1102 User Manual User Manual

Page 207

background image

6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-35

TRACe:DELete[:NAME]
This clears the specified arbitrary waveform memory. When this command is executed, a sine
wave is written to ARB1 to ARB8, a square wave is written to ARB9 to ARB12, and a triangle
wave is written to ARB13 to ARB16.
However, when output is on, the arbitrary waveform memory cannot be cleared. ([1, “Invalid with
output on”] error occurs.)

Syntax:

TRACe:DELete[:NAME]

Parameters:

ARB1 to ARB16

Command example:

TRAC:DEL ARB1

Response format:

None

Response example:

None


j) SYSTem subsystem

SYSTem:BEEPer:STATe
This controls the beep on/off setting. When the beep sound is enabled, beeps accompanying
cursor operations become enabled, and an operation error or a protected operation will be notified
with a beep.

Syntax:

SYSTem:BEEPer:STATe

Parameters:

OFF | 0 / ON | 1

Command example:

SYST:BEEP:STATe ON

Query

example:

SYST:BEEP:STATe?

Response format:

Response

example: 1

SYSTem:CONFigure:EXTIO
This controls the external control input enable/disable setting.

Syntax:

SYSTem:CONFigure:EXTIO

Parameters:

OFF | 0 / ON | 1

Command example:

SYST:CONF:EXTIO ON

Query

example:

SYST:CONF:EXTIO?

Response format:

Response example:

1