beautypg.com

GW Instek GDS-1000-U Series Quick start guide User Manual

Digital storage oscilloscope

background image

Digital Storage Oscilloscope

GDS-1000-U Series

QUICK START GUIDE

GW INSTEK PART NO. 82DS-1102UMA1

ISO-9001 CERTIFIED MANUFACTURER

S

AFETY INSTRUCTIONS

This section contains the basic safety symbols that may

appear on the accompanying user manual CD or on the

instrument. For detailed safety instructions and

precautions, please see the Safety Instructions chapter

in the user manual CD.

Safety Symbols

These safety symbols may appear in the user manual or

on the instrument.

Warning

Warning: Identifies conditions or

practices that could result in injury or

loss of life.

Caution

Caution: Identifies conditions or

practices that could result in damage

to the instrument or to other

properties.

DANGER High Voltage

Attention Refer to the Manual

Protective Conductor Terminal

Earth (ground) Terminal

Do not dispose electronic equipment

as unsorted municipal waste. Please

use a separate collection facility or

contact the supplier from which this

instrument was purchased.

Power Cord for the United Kingdom

When using the instrument in the United Kingdom,

make sure the power cord meets the following safety

instructions.

NOTE: This lead/appliance must only be wired by
competent persons.

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT: The wires in this lead are coloured in
accordance with the following code:

Green/ Yellow: Earth

Blue:

Neutral

Brown:

Live (Phase)

As the colours of the wires in main leads may not correspond with

the coloured marking identified in your plug/appliance, proceed as

follows:

The wire which is coloured Green & Yellow must be connected to

the Earth terminal marked with either the letter E, the earth symbol

or coloured Green/Green & Yellow.

The wire which is coloured Blue must be connected to the terminal

which is marked with the letter N or coloured Blue or Black.

The wire which is coloured Brown must be connected to the terminal

marked with the letter L or P or coloured Brown or Red.

If in doubt, consult the instructions provided with the equipment or

contact the supplier.

This cable/appliance should be protected by a suitably rated and

approved HBC mains fuse: refer to the rating information on the

equipment and/or user instructions for details. As a guide, a cable of

0.75mm

2

should be protected by a 3A or 5A fuse. Larger conductors

would normally require 13A types, depending on the connection

method used.

Any exposed wiring from a cable, plug or connection that is engaged

in a live socket is extremely hazardous. If a cable or plug is deemed

hazardous, turn off the mains power and remove the cable, any

fuses and fuse assemblies. All hazardous wiring must be

immediately destroyed and replaced in accordance to the above

standard.

G

ETTING STARTED

The Getting started chapter introduces the

oscilloscope’s main features, appearance, and set up

procedure.

Main Features

Model name

Frequency bandwidth Input channels

GDS-1052-U

DC–50MHz (–3dB)

2

GDS-1072-U

DC–70MHz (–3dB)

2

GDS-1102-U

DC–100MHz (–3dB) 2

Performance

• 250MSa/s real-time sampling rate
• 25GS/s equivalent-time sampling

rate

• 4k points record length
• Up to 10ns peak detection
• 2mV~10V vertical scale
• 1ns~50s time scale

Features

• 5.7 inch color TFT display
• Saving and recalling setups and

waveforms

• 19 automatic measurements
• Multi-language menu (12

languages)

• Math operation: Addition,

Subtraction, FFT

• Data logging
• Go-NoGo testing
• Edge, Video, Pulse width triggers

Interface

• USB 2.0 full-speed interface for

saving and recalling data

• Calibration output
• External trigger input
• USB B type (slave) interface for

remote control

Package Contents and Accessories

Standard Accessories

Part Number

Description

82DS-112AUEA1 User Manual CD

82DS-1102UMA1 Quick Start Guide

(this document)

GTP-070A-4

for GDS-1052-U,

GDS-1072-U

Passive probe,

70MHz, 10x, 1x

GTP-100A-4

for GDS-1102-U

Passive probe,

100MHz, 10x, 1x

Region

Dependent

Power cord x1

Optional Accessories

Part Number

Description

GTL-242

USB 2.0 Cable, type

A-B

GTL-110

Test Lead (BNC-

BNC)

GSC-006

Soft carry case

Display and Panel Overview

Display Overview

1

2

3 4

5

6

7

8

9

10

Description

1. Trigger position

2. Waveform position

3. Trigger status

4. Acquisition

5. Menu

6. Trigger condition

7. Frequency

8. Horizontal status

9. Vertical status

10. Waveform marker

Rear Panel

Description

1. Security lock slot

2. Fuse socket

3. Power cord socket

4. CAL output

5. USB B type port

Setting up the Oscilloscope

This section describes how to set up the oscilloscope

properly including adjusting the handle, connecting a

signal, adjusting the scale, and compensating the

probe. Before operating the oscilloscope in a new

environment, run these steps to make sure the

oscilloscope is functionally stable.
1. Pull both bases of the handle out slightly.

Front Panel

Description

1. LCD display

2. Function keys

3. Variable knob

4. Vertical position knob

5. VOLTS/DIV knob

6. Horizontal position

knob

7. Menu keys

8. Trigger level knob

9. Horizontal menu key 10. Trigger keys
11. TIME/DIV knob

12. EXT TRIG

13. Ground Terminal

14. CH2 Terminal

15. CH1/CH2 Math keys 16. CH1 Terminal
17. Probe Compensation

output

18. USB A type port

19. Power Switch

2. Turn to one of the three

preset positions.

3. Connect the power cord.

4. Press the power switch. The

display will become active

in approximately 10

seconds.

5. Reset the system by

recalling the factory

settings. Press the

Save/Recall key, then

Default Setup.

6. Connect the probe between the Channel1 input

terminal and probe compensation signal output

(2Vp-p, 1kHz square wave).

7. Set the probe attenuation voltage to x10.

This quick start guide contains proprietary information,

which is protected by copyright. All rights are reserved.

No part of this manual may be photocopied,

reproduced or translated to another language without

prior written consent of Good Will Corporation.
The information in this quick start guide was correct at

the time of printing. However, Good Will continues to

improve its products and therefore reserves the right to

change the specifications, equipment, and maintenance

procedures at any time without notice.

Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng
Dist., New Taipei City 236, Taiwan.