beautypg.com

6 setting superimposed ac waveform – GW Instek APS-1102 User Manual User Manual

Page 74

background image

4.1 Use as a DC Power Source

APS-1102 Programmable AC/DC Power Source

4-10

4.1.6 Setting superimposed AC waveform

Selects among 16 types of sine waves (SIN), square waves (SQU), and arbitrary waveforms (ARB).
Arbitrary waveforms are generated using data transfers via the USB interface.

See “4.6 Output of Arbitrary Waveforms”, for details of arbitrary waveforms.

To select a waveform, select

in the SET menu.

Operation steps

1. Press the

or

key to move the cursor to the

icon.

ENTER

CANCEL

Cursor

2. Press the

ENTER

key to display the selection box.

ENTER

CANCEL

Selection box

3. Press the

or

key to move the cursor to the waveform to be output.

ENTER

CANCEL