beautypg.com

GW Instek APS-1102 User Manual User Manual

Page 194

background image

6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-22

[SOURce:]SEQuence:STEP
Specifies the target step number for sequence editing. The step number specification ranges from
1 to 255.

Syntax:

[SOURce:]SEQuence:STEP

Parameters:

1 to 255

Command example:

SEQ:STEP 1

Query

example:

SEQ:STEP?

Response format:

Response example:

1

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
AC output voltage is set using the Vrms unit (when the waveform is SIN or SQU) or the Vp-p unit
(when the waveform is ARB). For the 100 V range, output voltage setting ranges from 0.0 to
140.0 Vrms or from 0.0 to 400.0 Vp-p, and for the 200 V range, it ranges from 0.0 to 280.0 Vrms
or from 0.0 to 800.0 Vp-p.
When in AC-EXT or AC+DC-EXT mode, the output AC voltage cannot be set or queried. ([3,
“Invalid in this mode”] error occurs.)

Syntax:

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]

Parameters:

0.0 to 140.0/0.0 to 400.0 (0.0 to 280.0/0.0 to 800.0)

Command example:

VOLT 100

Query

example:

VOLT?

Response format:

Response example:

100.0

[SOURce:]VOLTage:LIMit:HIGH
This sets the upper limit of the output voltage that can be set. However, a value that is at or below
the currently set cannot be specified. ([5, “Out of Limiter”] error occurs.)
For the 100 V range, the limit value setting ranges from 5.0 to 200.0 V, and for the 200 V range, it
ranges from 10.0 to 400.0 V.

Syntax:

[SOURce:]VOLTage:LIMit:HIGH

Parameters:

5.0 to 200.0 (10.0 to 400.0)

Command example:

VOLT:LIM:HIGH 200

Query

example:

VOLT:LIM:HIGH?

Response format:

Response

example: 200.0