6.3 Command Descriptions
APS-1102 Programmable AC/DC Power Source
6-22
[SOURce:]SEQuence:STEP
Specifies the target step number for sequence editing. The step number specification ranges from
1 to 255.
Syntax:
[SOURce:]SEQuence:STEP
Parameters:
1 to 255
Command example:
SEQ:STEP 1
Query
example:
SEQ:STEP?
Response format:
Response example:
1
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
AC output voltage is set using the Vrms unit (when the waveform is SIN or SQU) or the Vp-p unit
(when the waveform is ARB). For the 100 V range, output voltage setting ranges from 0.0 to
140.0 Vrms or from 0.0 to 400.0 Vp-p, and for the 200 V range, it ranges from 0.0 to 280.0 Vrms
or from 0.0 to 800.0 Vp-p.
When in AC-EXT or AC+DC-EXT mode, the output AC voltage cannot be set or queried. ([3,
“Invalid in this mode”] error occurs.)
Syntax:
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
Parameters:
0.0 to 140.0/0.0 to 400.0 (0.0 to 280.0/0.0 to 800.0)
Command example:
VOLT 100
Query
example:
VOLT?
Response format:
Response example:
100.0
[SOURce:]VOLTage:LIMit:HIGH
This sets the upper limit of the output voltage that can be set. However, a value that is at or below
the currently set cannot be specified. ([5, “Out of Limiter”] error occurs.)
For the 100 V range, the limit value setting ranges from 5.0 to 200.0 V, and for the 200 V range, it
ranges from 10.0 to 400.0 V.
Syntax:
[SOURce:]VOLTage:LIMit:HIGH
Parameters:
5.0 to 200.0 (10.0 to 400.0)
Command example:
VOLT:LIM:HIGH 200
Query
example:
VOLT:LIM:HIGH?
Response format:
Response
example: 200.0