beautypg.com

2 detailed command descriptions – GW Instek APS-1102 User Manual User Manual

Page 186

background image

6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-14

6.3.2 Detailed command descriptions

The following describes various command functions and syntax.

a) Meanings of symbols

 Angle brackets (< >):

Parameter symbols are enclosed in angle brackets. For example,
indicates the digital data format (NR1 type).

 A vertical bar ( | )

A parameter is used to alternative parameters. For example, “FIX|STEP”
indicates that either “FIX” or “STEP” can be used as a parameter.

 Square brackets ([ ])

An option header is enclosed by square brackets. For example,
“[SOURce:]LIST” indicates that “SOURce:” can be omitted.

 Bold (boldface)

Boldface characters are used to emphasize a syntax string when a
command is defined, such as TRIGger:SOURCe.

 

A triangular symbol is used to explicitly indicate that a space exists.


b) Remark

 Commands and queries are both included as APS-1102 commands, but for simplicity both are

referred to as commands.

Any command that includes a question mark (?) with a keyword is a query.
 Headers are not applied to command reply messages.

c) SOURce subsystem

[SOURce:]CURRent:LIMit:AVErage

This sets the upper limit for the output average current. The output average current limiter setting
ranges from 1.0 to 10.5 A (for 100 V range) or from 1.0 to 5.3 A (for 200 V range).


Syntax:

[SOURce:]CURRent:LIMit:AVErage

Parameter:

1.0 to 10.5 (1.0 to 5.3)

Command example:

CURR:LIM:AVE 5

Query

example:

CURR:LIM:AVE?

Response

format:

Response

example: 5.0