6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-32

STATus:WARNing:ENABle
This sets the warning event enable register. The setting ranges from 0 to 31999.

Syntax:

STATus:WARNing:ENABle

Parameters:

0 to 31999

Command example:

STAT:WARN:ENAB 1

Query

example:

STAT:WARN:ENAB?

Response format:

Response example:

1

STATus:WARNing[:EVENt]?
This returns the warning event register value. The response ranges from 0 to 31999.

Syntax:

STATus:WARNing[:EVENt]?

Parameters:

None

Query example:

STAT:WARN?

Response format:

Response

example: 0

STATus:WARNing:NTRansition
STATus:WARNing:PTRansition
This sets the warning transition filter (WRTF). The setting ranges from 0 to 31999.
 When the NTR filter is set to 1, WRER is set to 1 when WRCR changes from 1 to 0.
 When the PTR filter is set to 1, WRER is set to 1 when WRCR changes from 0 to 1.
 When the NTR and PTR filters are set to 1, WRER is set to 1 when WRCR changes.
 When the NTR and PTR filters are set to 0, changes in WRCR are not propagated to WRER.

Syntax:

STATus:WARNing:NTRansition

STATus:WARNing:PTRansition

Parameters:

0 to 31999

Command example:

STAT:WARN:NTR 16384

STAT:WARN:PTR

0

Query

example:

STAT:WARN:NTR?

STAT:WARN:PTR?

Response format:

Response example:

16384

0