6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-30

f) STATus subsystem

STATus:OPERation:CONDition?
This returns the operation condition register (OPCR). The response ranges from 0 to 20482.

Syntax:

STATus:OPERation:CONDition?

Parameters:

None

Query

example:

STAT:OPER:COND?

Response format:

Response

example: 16384

STATus:OPERation:ENABle
This sets the operation event enable register (OPEE). The setting ranges from 0 to 20482.

Syntax:

STATus:OPERation:ENABle

Parameters:

0 to 20482

Command example:

STAT:OPER:ENAB 16384

Query

example:

STAT:OPER:COND?

Response format:

Response

example: 16384

STATus:OPERation[:EVENt]?
This returns the operation event register (OPER) value. The response ranges from 0 to 20482.

Syntax:

STATus:OPERation[:EVENt]?

Parameters:

None

Query example:

STAT:OPER?

Response format:

Response

example: 16384