beautypg.com

GW Instek APS-1102 User Manual User Manual

Page 211

background image

6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-39

IDN?
This returns the model name, etc. The response message includes the “manufacturer, model name,
serial number, and firmware version”.

Syntax:

IDN?

Parameters:

None

Query

example:

IDN?

Response format:

Response example:

“GW Instek , APS-1102, 000001, Ver1.00”

OPC
When all operations

have been completed, this sets the standard event register OPC bit (BIT0).

OPC? returns 1 when all operations have been completed. However, the standard event register
OPC bit is not cleared to zero when

OPC? is executed.

Syntax:

OPC

Parameters:

None

Command

example:

OPC

Query

example:

OPC?

Response format:

Response

example: 1

RCL
This recalls status information stored to memory by

SAV. The selection range for the recall

memory is 1 to 30. However, recall is disabled when output is on. ([1, “Invalid with output on”]
error occurs.)

Syntax:

RCL

Parameters:

1 to 30

Command

example:

RCL 1

Response format:

None

Response example:

None