beautypg.com

GW Instek APS-1102 User Manual User Manual

Page 199

background image

6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-27

MEASure[:SCALar]:POWer:AC:APParent?
This returns the apparent power in VA units. The apparent power measurement full scale is 1400
VA. If the measured value exceeds the full scale, 9999 VA is returned as a measurement error.

Syntax:

MEASure[:SCALar]:POWer:AC:APParent?

Parameters:

None

Query example:

MEAS:POW:AC:APP?

Response format:

Response

example: 367

MEASure[:SCALar]:POWer:AC:PFACtor?
This returns the output power factor. The power factor measurement range is 0.00 to 1.00. When
the measured value exceeds the measurement range, 9.99 is returned as a measurement error.
The power factor is calculated as “effective power/apparent power”.

Syntax:

MEASure[:SCALar]:POWer:AC:PFACtor?

Parameters:

None

Query

example:

MEAS:POW:AC:PFAC?

Response format:

Response example:

0.68

MEASure[:SCALar]:POWer:AC:REACtive?
This returns the reactive power in Var units. The reactive power measurement full scale is 1400
Var. If the measured value exceeds the full scale, 9999 Var is returned as a measurement error.

Syntax:

MEASure[:SCALar]:POWer:AC:REACtive?

Parameters:

None

Query

example:

MEAS:POW:AC:REAC?

Response format:

Response

example: 269

MEASure[:SCALar]:POWer:AC[:REAL]?
The effective power is returned in W units. The effective power measurement full scale is 1200 W.
If the measured value exceeds the full scale, 9999 W is returned as a measurement error.

Syntax:

MEASure[:SCALar]:POWer:AC[:REAL]?

Parameters:

None

Query example:

MEAS:POW:AC?

Response format:

Response