6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-15

[SOURce:]CURRent:LIMit:PEAK:HIGH
This sets the upper limit of the output peak current (positive polarity). The output peak current
limiter (positive polarity) setting ranges from 10.0 to 42.0 A (for 100 V range) or from 5.0 to 21.0
A (for 200 V range).


Syntax:

[SOURce:]CURRent:LIMit:PEAK:HIGH

Parameters:

10.0 to 42.0 (5.0 to 21.0)

Command example:

CURR:LIM:PEAK:HIGH 10

Query

example:

CURR:LIM:PEAK:HIGH?

Response

format:

Response

example: 10.0

[SOURce:]CURRent:LIMit:PEAK:LOW
This sets the upper limit for output peak current (negative polarity). The output peak current
limiter (negative polarity) setting ranges from

10.0 to 42.0 A (for 100 V range) or from 5.0 to

21.0 A (for 200 V range).

Syntax:

[SOURce:]CURRent:LIMit:PEAK:LOW

Parameters:

10.0 to 42.0(5.0 to 21.0)

Command example:

CURR:LIM:PEAK:LOW

10

Query

example:

CURR:LIM:PEAK:LOW?

Response format:

Response

example:

10.0

[SOURce:]FREQuency[:IMMediate]
This sets the output frequency. When in AC-EXT/AC-SYNC/AC+DC-EXT/AC+DC-SYNC
mode, the frequency cannot be set. ([3, “Invalid in this mode”] error occurs.)
The frequency setting ranges from 1.0 to 550.0 Hz.

Syntax:

[SOURce:]FREQuency[:IMMediate]

Parameters:

1.0 to 550.0

Command example:

FREQ 50

Query

example:

FREQ?

Response

format:

Response

example: 50.0